E03 Refrigerators and freezers for storing vaccines and freezing water-packs
Note: the PIS 2000 catalogue (and new items added to the PIS since publication of the 2000 edition) has been definitely abolished for this E003 category on 1 October 2010. The full revision of performance specifications and verification protocols has been achieved and endorsed by the steering committee at that date. All items included in the PIS catalogue are considered as not suitable for UN purchase unless they are PQS prequalified and part of the list to be found through the link below:
All new applications for prequalification of refrigerators and freezers for storing vaccines and freezing water-packs must follow PQS procedures as described in the Guideline for manufacturers of vaccine refrigerators, vaccine freezers and icepack freezers (WHO/PQS/E03/GUIDE.1.3) and Guideline for manufacturers of solar power systems (WHO/PQS/E03/GUIDE.2.3). All items prequalified 4 months prior to the review date will be subjected to the 2011 annual review. The first version of the performance specifications and verification protocols for E03 category refrigerators and freezers for storing vaccines and freezing water-packs were approved by the PQS Steering Group on 14 September 2007. The transitional period to have PIS products for submission of prequalification was set as 31 March 2009. However, because of the extensive review process of performance specifications and verification protocols, this period had been extended to 1 October 2010.
Vaccine freezer or combined vaccine/icepack freezer: compression cycle
-
PQS performance specification, WHO/PQS/E03/FZ01.2
pdf, 150kb -
PQS independent type-testing protocol, WHO/PQS/E03/FZ01-VP.2
pdf, 123kb
Icepack freezer
-
PQS performance specification WHO/PQS/E03/FZ02.2
pdf, 88kb -
PQS independent type-testing protocol WHO/PQS/E03/FZ02-VP.2
pdf, 111kb
Refrigerator or combined refrigerator-icepack freezer: compression cycle
-
PQS performance specification WHO/PQS/E03/RF01.2
pdf, 161kb -
PQS independent type-testing protocol WHO/PQS/E03/RF01-VP.2
pdf, 130kb
Refrigerator or combined refrigerator-icepack freezer: absorption cycle
-
PQS performance specification WHO/PQS/E03/RF02.2
pdf, 102kb -
PQS independent type-testing protocol WHO/PQS/E03/RF02-VP.2
pdf, 133kb
Ice-lined refrigerator or combined refrigerator-icepack freezer: compression cycle
-
PQS performance specification WHO/PQS/E03/RF03.2
pdf, 162kb -
PQS independent type-testing protocol WHO/PQS/E03/RF03-VP.2
pdf, 128kb
Refrigerator or combined refrigerator-icepack freezer: compression cycle. For solar powered rechargeable battery storage
-
PQS performance specification WHO/PQS/E03/RF04.2
pdf, 165kb -
PQS independent type-testing protocol WHO/PQS/E03/RF04-VP.2
pdf, 132kb
Refrigerator or combined refrigerator-icepack freezer: compression-cycle. For solar direct drive without battery storage
-
PQS performance specification WHO/PQS/E03/RF05.2
pdf, 166kb -
PQS independent type-testing protocol WHO/PQS/E03/RF05-VP.2
pdf, 149kb
Refrigerator or combined refrigerator and water-pack freezer: compression cycle. Solar direct drive with ancillary rechargeable battery
-
PQS performance specification WHO/PQS/E03/RF06.1
pdf, 167kb -
PQS independent type-testing protocol WHO/PQS/E03/RF06-VP.1
pdf, 148kb
Solar power system for compression-cycle vaccine refrigerator or combined refrigerator-icepack freezer
-
PQS performance specification WHO/PQS/E03/PV01.2
pdf, 114kb -
PQS independent type-testing protocol WHO/PQS/E03/PV01-VP1.2
pdf, 85kb -
PQS quality assurance protocol WHO/PQS/E03/PV01-VP2.2
pdf, 121kb